IEC Standards for the Safety and. Efficacy of Medical Electrical Equipment . Introduction. It might, perhaps, be a little too self-evident to say that there is no. The new IEC standard for the in-service and post repair testing of electromedical devices introduces new requirements. These and their. STANDARD. IEC. CEI. NORME. INTERNATIONALE. First edition. Première édition. Medical electrical equipment –. Recurrent test and test after.

Author: Nikobar Faekazahn
Country: Dominican Republic
Language: English (Spanish)
Genre: Business
Published (Last): 22 December 2006
Pages: 374
PDF File Size: 18.38 Mb
ePub File Size: 13.29 Mb
ISBN: 930-3-90802-171-7
Downloads: 14282
Price: Free* [*Free Regsitration Required]
Uploader: Yozshujinn

In addition, this measurement is only taken in a single polarity and is similar to a dielectric test at mains potential using a current limited mains frequency supply. One example is the culture of organizations, which can affect the type of test equipment used and the frequency of testing. Please provide your name and email to continue.

Stay aware of moving parts, open conductors, live components, heat, etc. For idc, the test limit for a Class I device including 26353 power cable not exceeding 3 meters is mV. IEC You can find in-depth information on IECincluding in-service test requirements in this part of the free guide. The alternative method is similar to a dielectric strength test at mains potential, using a current limited voltage source at mains frequency.

Ultrasound Systems and Probes If the buzz at the recent RSNA annual meeting is any indication of market trends, the ultrasound sector is hotter…. Testing Times Each part of eic medical device market has different electrical safety testing requirements. Ensure that the operator of safety test equipment is properly trained on both the safety analyzer and the device under test to prevent unneccessary danger during the safety jec.

The introduction of IEC is intended to streamline this position and harmonize all standards that aim to control the safety of electromedical EM devices used in the treatment, care, and diagnosis of patients. Conclusion here you will find a brief overview of what has been covered in the guide and what the IEC standard will provide. Our 62335 are in Swiss francs CHF. Preview Abstract IEC Recently, new test technology has been pioneered in the form of a new low-energy, high-current test that overcomes the previous contact-resistance problems that inhibited the wider application of protective ground testing using 1A or mA test currents.

  HIOS CL-6500 PDF

An Introduction to IEC – 24×7 Magazine

Acceptance testing, also referred to as initial or reference testing. As far as possible, it is an attempt at standardizing the safe 6235 and testing of ME equipment, while respecting specific local requirements and meeting increasing demands for risk management.

Introduction This section talks about electrical current, the human body and how it conducts current, and IEC Body Model. IEC Ground Bond Test The ground bond test proves the integrity of the low-resistance connection between the ground conductor and any metal 26353 parts, which may become live in fault situations with Class I medical devices.

Ensure that leakage measurements are performed while the equipment is in full operation mode, including its subsystems and components. The highest test reading will determine the pass or fail result of this test in comparison with different test limits included in IEC for different types of equipment. After ic and repair testing—carried out following a repair, adaptation, or product upgrade.

Another factor can be the environment in which testing is undertaken, which can vary from the production line, the laboratory, an operating theater, to the patient ward. IEC Leakage Testing Research has shown that it is current rather than voltage that is the source of electricity-related injuries and deaths. Figures 1, 2, and 3 provide a schematic representation of the equipment leakage test on Class I grounded ME equipment.

When determining the correct means of testing a specific medical device, ensure that the chosen safety test procedures are applicable to the device under test and are clearly documented for future use. Record Keeping This section covers gathering and comparison of data collected, including what information should be included in the data logged.

The differential leakage measurement method is also only able to measure the AC component. It is often part of a service carried out by in-hospital mechanical or clinical engineering teams.

An Introduction to IEC 62353

Importantly, the new low-current test technology enables valid ground continuity tests to be carried out using battery-powered testers, significantly increasing the portability and versatility of handheld safety analyzers used in in-service safety testing routines, significantly speeding up the testing process. Clearly, safety testing at the design stage and at the end of the production line are vitally important, but what about when the equipment enters service?

  CEIDG INTERAKTYWNY PDF

Higher test currents of 25A or 10A have been traditionally favored, based largely on IEC requirements. Housing enclosure—look for damage, cracks, etc; Contamination—look for obstruction of moving parts, connector pins, etc; Cabling supply, applied parts, etc —look for cuts, wrong connections, etc; Fuse rating—check correct values after replacement; Markings and labeling—check the integrity of safety markings; and Integrity of mechanical parts—check for any obstructions.

In meeting these aims, IEC incorporates tests beyond those of type testing. England Wales Scotland Ireland N. This standard is not applicable to the assembly of ME systems.

Download Your Free Guide to IEC from Rigel Medical Today

IEC requires a minimum test current of mA, either AC or DC, but when using a DC test current, the resistance must be tested in both polarities of the test current. This standard is not suitable to assess whether ME equipment or ME systems or any other equipment comply with the relevant standards for their design.

Appreciate the basics of electrical safety.

Introduction to IEC This edition constitutes a technical revision including the following main revisions: IEC specifies three methods— direct, differential, and alternative—that can be used to determine the leakage of EM equipment.

If the buzz at the recent RSNA annual meeting is any indication of market trends, the ultrasound sector is hotter…. All patient connections of a single function within an applied part shall be connected together BF and CF and measured one at a time. The disadvantages of using the alternative method are that measurements cannot be compared with previous IEC tests, and those active parts of the circuitry that require mains potential between live and neutral cannot be tested for possible leakage.

The direct leakage method included in IEC is the same as that in IECmeasuring the true leakage through a body model measuring device to ground.